Because the designs of computers are different, only general installation instructions are 
given. Please refer your computer’s reference manual whenever in doubt. 
1.  Connect the USB cable to the USB B Connector of the module. 
2.  Plug the included power supply into the 5V Connector (optional). 
3.  Now connect the other end from the USB cable ( A-Plug) to the A-Connector at 
your PC. 
HARDWARE INSTALLATION : 
6 5 
EX
EX
EX
-
-
-
1300
1300
1300
English
English
English
EX
EX
EX
-
-
-
1300
1300
1300
English
English
English
1 
Das USB zu Parallel Modul ist zur Umsetzung von USB auf eine Parallele Schnitt-
stelle für den Anschluss von High Speed Parallelen Peripherie Geräten (z.B. 
Drucker, Scanner usw.) geeignet. Das Modul ist Hot Plug & Play fähig. Für die 
Einstellungen der I/O Adressen und Interrupts sind keine Jumper und Einstellun-
gen notwendig. Sie werden vom System und beim Installieren des Betriebssys-
tems automatisch vorgenommen. 
BESCHREIBUNG & TECHNISCHE DATEN : 
AUFBAU : 
Kompatibilität:  USB 1.1 & 2.0 Anschluss 
Betriebssysteme: WIN 98/ME/2000/XP/Server 2003/Vista/MAC 
Anschlüsse:  36 Pin Centronics Buchse, 1 x USB A-Stecker 
Lieferumfang:  1 x USB zu Parallel Modul, Anleitung, CD 
Zertifikate:  CE / FCC / RoHS / WEEE       DE97424562 
DRIVER INSTALLATION : 
JUMPER EINSTELLUNG & ANSCHLÜSSE: 
CLEANING : 
For cleaning please use only a dry fluffless cloth and remove the dirt with gently pressu-
re. In the area of the connectors please make sure that no fibres from the cloth remain 
in the connectors. Attention! Never use a moist or wet cloth for cleaning! 
Windows 98 ME 2000 XP Server 2000 and Server 2003 (32-bit): 
Windows will recognize a new “USB Parallel Device“ and open the hardware assistant. 
Please choose manual installation and put the driver CD into your CD-Rom drive ( as 
sample D:). Now enter the Path "D:\USB_to_IO\ USB_to_Parallel\WIN98_ME_2K_XP”  
into the box for the Path/Source and click at >next/continue<. Now Windows will 
search for the drivers in the specified directory. Follow the hardware assistant and finish 
the installation. If Windows recognizes other new devices repeat the above described 
steps. Attention! Restart Windows in any case after installing the drivers. 
CHECK THE INSTALLED DRIVER: 
Click at Start<>Run< then enter “compmgmt.msc“  and click at >OK<. In the window 
that opens select >Device Manager<. Under ”Ports (COM and LPT)“ you should find 
one more new „USB Parallel Port„ as sample (LPT3). If you see this or similar entries 
the module is installed correctly. 
CHANGE PORT NUMBER: 
If you like to change the port number for example LPT 2 to LPT 3, open the >Device Man-
ager<  click at >LPT2<, >Settings< and then >Advance<. There you can choose between 
LPT 1 up to 3. 
INSTALL THE PERIPHERAL DEVICE: 
Now you can install a parallel peripheral device to the module. 
Windows XP and Server 2003 (64-bit): 
Windows will recognize a new “USB Parallel Device“ and open the hardware assistant. 
Windows will recognize the device automatically and install it. Follow the hardware 
assistant and finish the installation. Restart Windows in any case after installing the 
drivers. 
CHECK THE INSTALLED DRIVER: 
Click at Start<>Run< then enter “compmgmt.msc“  and click at >OK<. In the window 
that opens select >Device Manager<. And open „Universal Serial Bus Controller“ 
you should find the entry „USB Parallel Converter“. If you see this or similar entries 
the module is installed correctly. 
INSTALL THE PRINTER DEVICE: 
To install a printer please proceed with the following steps: 
Click at >Start< >Settings< >Printer and Fax devices< >Add printer< >Next< >Local 
printer<. Select one of the new ports “USB 001 or USB 002 (Virtual printer port for 
USB)”  to install a new printer to the module. Now follow the Hardware assistant to 
complete the Installation of your printer. 
DRIVER INSTALLATION : 
Windows Vista (32 & 64-bit): 
Windows will recognize a new “USB Parallel Device“ and open the hardware assistant. 
Windows will recognize the device automatically and install it. Follow the hardware 
assistant and finish the installation. Restart Windows in any case after installing the 
drivers. 
CHECK THE INSTALLED DRIVER: 
Click at the “Start Windows Logo< then enter “compmgmt.msc“ at the “search box” 
and select it on the top under “Programs”. In the window that opens select >Device 
Manager<.  And open „USB Controller“ there you should find the entry „USB Parallel 
Converter“. If you see this or similar entries the module is installed correctly. 
INSTALL THE PRINTER DEVICE: 
To install a printer please proceed with the following steps: 
Click at >Start< >Settings< >Printer and Fax devices< >Add printer< >Next< >Local 
printer<. Select one of the new ports “USB 001 or USB 002 (Virtual printer port for 
USB)”  to install a new printer to the module. Now follow the Hardware assistant to 
complete the Installation of your printer. 
MAC: 
There are no MAC OS drivers for this product but  the modules are supported by the 
most versions of MAC OS. Because each individual version of MAC OS is different, 
sadly we cant provide a installation instruction. Please refer to the installation manual for 
IO ports from your MAC OS version ! 
JUMPER SETTING & CONNECTORS: 
USB B-Connector: 
USB 2.0 B-Connector: 
Pin Signal  Pin  Signal 
1 VCC  4  GND 
2 DATA-     
3 DATA+     
Attention! 
Never plug in with 
force or in wrong 
direction. 
36 Pin  Centronics  
 Parallel Stecker 
USB 1.1  
A-Stecker 
Pin Signal Pin  Signal  Pin  Signal 
1 STROBE 13  SELECT  25  GND 
2  DATA 0  14  AUTO FEED  26  GND 
3 DATA 1 15  N/C  27  GND 
4  DATA 2  16  0 V  28  GND 
5  DATA 3  17  Chassis GND  29  GND 
6  DATA 4  18  +5V PULLUP  30  Reset GND 
7 DATA 5 19  GND  31 RESET 
8 DATA 6 20  GND  32  FAULT 
9  DATA 7  21  GND  33  0 V 
Parallel Centronics 36 Pin : 
10 ACKNOWL 22  GND  34  N/C 
11 BUSY 23  GND  35 +5V DC 
12  PAPER OUT  24  GND  36  SLCT IN 
Centronics 36F: 
Bedienungsanleitung
Bedienungsanleitung
Vers. 3.0 / 12.02.08  
Specyfikacje produktu
| Marka: | EXSYS | 
| Kategoria: | Kable do komputerów PC i urządzeń peryferyjnych | 
| Model: | EX-1300 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z EXSYS EX-1300, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Kable do komputerów PC i urządzeń peryferyjnych EXSYS
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            Instrukcje Kable do komputerów PC i urządzeń peryferyjnych
- PureLink
- Shure
- NZXT
- Blaupunkt
- Chief
- Worx
- Kenwood
- Energy Sistem
- Audiovox
- Inno-Hit
- Sabrent
- Equip
- Kicker
- Fluke
- Comprehensive
Najnowsze instrukcje dla Kable do komputerów PC i urządzeń peryferyjnych
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         12 Stycznia 2025
                        
                    
                                                            
                        
                         10 Stycznia 2025
                        
                    
                                                            
                        
                         4 Stycznia 2025
                        
                    
                                                            
                        
                         2 Stycznia 2025
                        
                    
                                                            
                        
                         2 Stycznia 2025
                        
                    
                                                            
                        
                         2 Stycznia 2025
                        
                    
                                                            
                        
                         2 Stycznia 2025
                        
                    
                                                            
                        
                         1 Stycznia 2025
                        
                    
                                                            
                        
                         30 Grudnia 2025