® U.S. Registered Trademark. Patents
pending. Copyright © 2019 Resideo.
All rights reserved.
69-2815EFS-07
Smart Thermostat 9000
Color Touchscreen
TH9320WF
Installation Guide
72º
SET TO
72
º
HOME FAN SYSTEM MENU
Fri, Jun 14, 2013
6:30 pm
INDOOR
45% Humidity
OUTDOOR
S USTAT
cool mode
80 /55% ˚Humidity
following schedule
Connected by
the TCC app
72
°
HOME. Touch to display Home screen.
FAN. Select fan mode.
SYSTEM. Select system mode (heat/cool).
MENU. Touch to display options. Start here
to set a program schedule.
Current schedule. Change temperature
setting and select temporary or permanent
hold.
Indoor conditions. Shows indoor
temperature and humidity.
Current date and time.
Current status. Shows system mode (heat/
cool).
Outdoor conditions. Outdoor temperature
and humidity appear after registration.

69-2815EFS—07 2
LEVEL
HERE
M34819
C
K
Rc
R
W-
O/B
Y
G
W2-
Aux/E
Y2
L
M34500A
Read and save these instructions
Wallplate installation
1. Separate wallplate from thermostat.
2. Mount wallplate as shown below.
Drill 3/16" holes for drywall. Drill 7/32" holes for plaster.
Wall anchors
Wallplate
Wire hole
Mounting screws
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash.
Wallplate
Back of
Thermostat

3 69-2815EFS—07
CCommon wire from secondary side of cooling transformer (if 2 transformers).
KOptional C-wire adaptor.
Rc Cooling power. Connect to secondary side of cooling system transformer.
RHeating power. Connect to secondary side of heating system transformer.
W-O/B 1st stage heat relay. Or changeover valve for heat pumps.
Y1st stage compressor contactor.
GFan relay.
W2-Aux/E 2nd stage heat relay. Or heat pump auxiliary/Emergency heat relay.
Y2 2nd stage compressor contactor.
LHeat pump system monitor.
Jumper Loop, a plug with a wire loop used to connect the to the terminals, R Rc
Leave jumper loop in place in single transformer systems. Remove (unplug)
jumper loop in two transformer systems.
Terminal Designations
Wiring
C
K
Rc
R
W-
O/B
Y
G
W2-
Aux/E
Y2
L
Remove
jumper loop
ONLY if you
have both
R and Rc
wires.
Terminal
release
Terminal
holes
accept one
wire
Specyfikacje produktu
Marka: | Honeywell |
Kategoria: | termostat |
Model: | TH9320WF5003/U |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Honeywell TH9320WF5003/U, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje termostat Honeywell
5 Kwietnia 2025
10 Marca 2025
28 Stycznia 2025
18 Stycznia 2025
18 Stycznia 2025
18 Stycznia 2025
18 Stycznia 2025
18 Stycznia 2025
17 Stycznia 2025
16 Stycznia 2025
Instrukcje termostat
- termostat HomePilot
- termostat Watts
- termostat ORNO
- termostat Tylö
- termostat Emko
- termostat Daikin
- termostat MundoControl
- termostat RWE
- termostat Cotech
- termostat Renkforce
- termostat Veria
- termostat OJ ELECTRONICS
- termostat Wallair
- termostat Westfalia
- termostat Elektrobock
Najnowsze instrukcje dla termostat
9 Kwietnia 2025
9 Kwietnia 2025
8 Kwietnia 2025
8 Kwietnia 2025
7 Kwietnia 2025
7 Kwietnia 2025
6 Kwietnia 2025
6 Kwietnia 2025
5 Kwietnia 2025
5 Kwietnia 2025