Instrukcja obsługi Honeywell Y9120W Sundial RF2 Pack 4
                    Honeywell
                    
                    Kontrola temperatury
                    
                    Y9120W Sundial RF2  Pack 4
                
                                
    Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Honeywell Y9120W Sundial RF2 Pack 4 (26 stron) w kategorii Kontrola temperatury. Ta instrukcja była pomocna dla 11 osób i została oceniona przez 6 użytkowników na średnio 4.0 gwiazdek
                        Strona 1/26
                    
                    
                    
User Guide
Y9120W Sundial RF2 Pack 4
How to use:
  ST9120C Wireless Enabled Timer
  CS92A Wireless Cylinder Thermostat
Honeywell Control Systems Ltd.
Arlington Business Park,
Bracknell
Berkshire
RG12 1EB
Technical Help Desk: 08457 678999
www.honeywelluk.com
50047645-002 A
© 2011 Honeywell International Inc.
System Components
Energy Efficiency and the Environment
Home energy use is responsible for more than ¼ of the total UK carbon emissions 
which contribute to climate change. Heating and hot water systems based on 
boilers account for   of this figure, so it is important to understand how your 
controls can help to maximize energy efficiency while maintaining your comfort.
Your Timer should be used in conjunction with appropriate temperature controls. In 
order to save energy the following general points should be observed:
1.  Ensure your system contains a room thermostat (where appropriate) and a hot 
water thermostat, and that  it is set to an appropriate temperature level, typically 
20°C
2.  Programme your heating (and hot water) to be off when you are not in the 
house. If you are concerned about possible frost damage to any exposed pipe 
work, it is advisable to fit a frost protection system – your installer can advise 
you about this.
3.  Think about how you use your domestic hot water – if you have a storage 
system, it is not necessary to have this switched on all the time, even when you 
are in the house.
4. Consider the heat up times required for your central heating. Every home 
responds differently when the heating is switched on. Adjust the start time so 
that you are not cold when you get up in the morning. A shorter heat up time is 
required for other heating periods.
5.  In the evening, when the house is up to temperature, it is often possible to 
switch off the heating up to an hour before you go to bed, without any noticeable 
reduction in comfort.
PLEASE RESPECT YOUR ENVIRONMENT!
Take care to dispose of this product and any 
packaging or literature in an appropriate way
This document is to be left with the user
and forms part of a Home Information Pack
WHAT IS A PROGRAMMER?
...an Explanation for Householders (as recommended by the Energy Savings Trust)
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and 
domestic hot water on and off at the same time, while others allow the domestic hot water and heating 
to come on and go off at different times. Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On 
some programmers you must also set whether you want the heating and hot water to run continuously, 
run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently 
off. The time on the programmer must be correct. Some types have to be 
adjusted in spring and autumn at the changes between Greenwich Mean 
Time and British Summer Time. You may be able to temporarily adjust the 
heating programme, for example, ‘Override’, ‘Advance’, or ‘Boost’. These 
are explained in the manufacturer’s instructions. The heating will not work 
if the room thermostat has switched the heating off. And, if you have a hot-
water cylinder, the water heating will not work if the cylinder thermostat 
detects that the hot water has reached the correct temperature.
WHAT IS A CYLINDER THERMOSTAT?
...an explanation for Householders (as recommended by the Energy Savings Trust)
A cylinder thermostat switches on and off the heat supply from the boiler to the hot water cylinder. 
It works by sensing the temperature of the water inside the cylinder, switching on the water heating 
when the temperature falls below the thermostat setting, and switching it off once this set temperature 
has been reached.
Turning a cylinder thermostat to a higher setting will not make the water heat up any faster. How quickly 
the water heats up depends on the design of the heating system, for example, the size of boiler and 
the heat exchanger inside the cylinder.
The water heating will not work if a time-switch or programmer has switched it off. And the cylinder 
thermostat will not always switch the boiler off, because the boiler sometimes needs to heat the 
radiators.
Cylinder thermostats are usually fitted between one quarter and one third of the way up the cylinder. 
The cylinder thermostat will have a temperature scale marked on it, and it should be set at between 
60C and 65C, then left to do its job. This temperature is high enough to kill off harmful bacteria in the 
water, but raising the temperature of the stored hot water any higher will result in wasted energy and 
increase the risk of scalding.
Location
ST9120C
CS92A
(typically next to hot water cylinder, in bedroom)
This section is to be completed by the Installer
Specyfikacje produktu
| Marka: | Honeywell | 
| Kategoria: | Kontrola temperatury | 
| Model: | Y9120W Sundial RF2 Pack 4 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Honeywell Y9120W Sundial RF2 Pack 4, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Kontrola temperatury Honeywell
                        
                         6 Lutego 2025
                        
                    
                                                            
                        
                         18 Stycznia 2025
                        
                    
                                                            
                        
                         17 Stycznia 2025
                        
                    
                                                            
                        
                         16 Stycznia 2025
                        
                    
                                                            
                        
                         4 Lipca 2024
                        
                    
                                                            
                        
                         3 Lipca 2024
                        
                    
                                                            
                        
                         1 Lipca 2024
                        
                    
                                                            
                        
                         30 Czerwca 2024
                        
                    
                                                            
                        
                         28 Czerwca 2024
                        
                    
                                                            Instrukcje Kontrola temperatury
- Nefit
- Danfoss
- Remeha
- AEG
- Infresco
- Velbus
- Samson
- EQ-3
- Bulex
- Sorel
- Sabi
- Brennenstuhl
- Dimplex
- Atag
- Thermomax
Najnowsze instrukcje dla Kontrola temperatury
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         4 Kwietnia 2025
                        
                    
                                                            
                        
                         26 Marca 2025
                        
                    
                                                            
                        
                         19 Marca 2025
                        
                    
                                                            
                        
                         19 Marca 2025
                        
                    
                                                            
                        
                         12 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025
                        
                    
                                                            
                        
                         10 Marca 2025