The INNOVATIVE SMALLEST and
Flush 1 relay
ORDERING CODE
Z-WAVE FREQUENCY
ZMNHAA2
868,4 MHz
ZMNHAA3
921,4 MHz
ZMNHAA4
908,4 MHz
ZMNHAA5
869,0 MHz
ZMNHAA6
916,0 MHz
This Z-Wave module is used for switching on or
o the electrical device (e.g. light, fan, etc ...). ff
The module can be controlled either through
Z-wave network or through the wall switch.
The module is designed to be mounted inside
a “ ”flush mounting box , hidden behind a
traditional wall switch.
Module measures power consumption of
electrical device and supports connection of
digital temperature sensor. It is designed to act
as repeater in order to improve range and
stability of Z-wave network.
Supported switches
Module supports switches mono-stable
(push button) and switches. The bi-stable
module is factory set to operate with -stable bi
switches.
Installation
Before the installation disconnect power
supply.
Connect the module according to
electrical diagram.
Locate the antenna far from metal
elements (as far as possible).
Do not shorten the antenna.
Danger of electrocution!
Module installation requires a great degree
of skill and may be performed only by a
qualified and licensed electrician.
Even when the module is turned off,
voltage may be present on its terminals.
Any works on configuration changes
related to connection mode or load must be
always performed by disconnected power
supply (disable the fuse).
Note!
Do not connect the module to loads exceeding
recommended values. Connect the module
only in accordance to the below diagrams.
Improper connections may be dangerous.
Package conten ts
Flush 1 relay
Electrical diagram 230VAC
Notes for the diagram:
Electrical diagram 24VDC
Notes for the diagram:
Durability of the module depends on applied
load. For resistive load (light bulbs, etc.) and
10A current consumption of each individual
electrical device, the durability exceeds
100.000 switches of each individual electrical
device.
Module Inclusion (Adding to Z-wave
network)
Connect module to power supply (with
temperature sensor connected - if
purchased),
bring module within maximum 1 meter (3
feet) of the main controller,
enable add/remove mode on main
controller
auto-inclusion (30 minutes after
connected to power supply) or
press service button for more than 2 S
second or
press push button three times within 3I1 s
(3 times change switch state within 3
seconds).
Module Exclusion/Reset (Removing
from Z-Wave network)
Connect module to power supply
bring module within maximum 1 meter (3
feet) of the main controller,
enable add/remove mode on main
controller
press service button for more than 6 S
second or
press push button I1 five times within 3s (5
times change switch state within 3
seconds) in the first 60 seconds after the
module is connected to the power supply.
By this function all parameters of the module
are set to default values and own ID is deleted
If service button S is pressed more than 2 and
less than 6 second module is excluded, but
configuration parameters are not set to default
values.
Association
Association enables Flush 1 relay module to
transfer commands inside Z-Wave network
directly (without main controller) to other
Z-Wave modules.
Associated Groups:
Group 1: basic on/off (triggered at change of
the output Q state and reflecting its state) up to
16 nodes.
Group 2: basic on/off (triggered at change of
the input I2 state and reflecting its state) up to
16 nodes.
Group 3: basic on/off (triggered at change of
the input I3 state and reflecting its state) up to
16 nodes.
Group 4: default reporting group (reserved for
the main controller).
Configuration parameters
Parameter no. Input 1 switch type 1 –
Available configuration parameters (data type
is 1 Byte DEC):
default value 1
mono-stable switch type (push button) 0
-stable switch type 1 bi
Parameter no. 2 Input 2 contact type –
Available configuration parameters (data type
is 1 Byte DEC):
default value 0
0 NO (normally open) input type
1 NC (normally close) input type
Parameter no. 3 Input 3 contact type –
Available configuration parameters (data type
is 1 Byte DEC):
default value 0
0 NO (normally open) input type
1 NC (normally close) input type
Parameter no. 10 - Activate / deactivate
functions ALL ON/ALL OFF
Available configuration parameters (data type
is 1 Byte DEC):
default value 255
255 - ALL ON active, ALL OFF active
- ALL ON is not active ALL OFF is not 0
active
- ALL ON is not active ALL OFF active 1
- ALL ON active ALL OFF is not active 2
Flush 1 relay module responds to commands
ALL ON / ALL OFF that may be sent by the
main controller or by other controller belonging
to the system.
Parameter no. 11 - Automatic turning off
relay after set time
Available configuration parameters (data type
is 2 Byte DEC):
Default value 0
- Auto OFF disabled 0
1 65535 = 0,01second 655,35 – –
seconds Auto OFF enabled with define
time, step is 10mseconds.
Parameter no. 30 - Saving the state of the
relay after a power failure
Available configuration parameters (data type
is 1 Byte DEC):
default value 0
Flush 1relay module saves its state 0 –
before power failure (it returns to the last
position saved before a power failure)
- Flush 1relay module does not save the 1
state after a power failure, it returns to
"off" position.
N
Neutral lead
L
Live lead
Q
Output for electrical device
I3
Input for switch /push button or sensor
I2
Input for switch /push button or sensor
I1
Input for switch /push button
TS
Terminal for digital temperature sensor
(only for Flush 1 relay module
compatible digital temperature sensor,
which must be ordered separately).
N
+ VDC
L
- VDC
Q
Output for electrical device
I3
Input for switch /push button or sensor
I2
Input for switch /push button or sensor
I1
Input for switch /push button
TS
Terminal for digital temperature sensor
(only for Flush 1 relay module
compatible digital temperature sensor,
which must be ordered separately).
S
Service button (used to
add or remove module
from the Z-Wave
network).
Specyfikacje produktu
| Marka: | Qubino |
| Kategoria: | Niesklasyfikowane |
| Model: | ZMNHAA2 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Qubino ZMNHAA2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Qubino
3 Października 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
Instrukcje Niesklasyfikowane
- Alpha Tools
- STANDIVARIUS
- Gustavsberg
- Maxi-Cosi
- Zehnder
- Genie
- Silva
- Daikin
- Jomox
- Swarovski Optik
- VitalMaxx
- Manley
- Onkyo
- PureTools
- EcoFlow
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025