Instrukcja obsługi Shelly Pro 3EM
                    Shelly
                    
                    inteligentny dom
                    
                    Pro 3EM
                
                                
    Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Shelly Pro 3EM (2 stron) w kategorii inteligentny dom. Ta instrukcja była pomocna dla 25 osób i została oceniona przez 13 użytkowników na średnio 4.6 gwiazdek
                        Strona 1/2
                    
                    
                    
EN
USER AND SAFETY GUIDE
SHELLY PRO 3EM
THREE-PHASE ENERGY METER
Read before use
This document contains important technical and safety informa-
tion about the device, its safety use and installation. 
⚠CAUTION! Before beginning the installation, please read careful-
ly and entirely this guide and any other documents accompanying 
the device. Failure to follow the installation procedures could lead to 
malfunction, danger to your health and life, violation of law or refus-
al of legal and/or commercial guarantee (if any). Allterco Robotics 
EOOD is not responsible for any loss or damage in case of incorrect 
installation or improper operation of this device due to failure of fol-
lowing the user and safety instructions in this guide.
Product Introduction 
Shelly®  is a line of innovative microprocessor-managed devices, 
which  allow  remote  control  of  electric  circuits  through  a  mobile 
phone,  tablet,  PC,  or  home  automation  system.  Shelly®  devices 
can work standalone in a local Wi-Fi network or they can also be 
operated through cloud home automation services. Shelly Cloud is 
a service that can be accessed using either Android or iOS mobile 
application,  or  with  any  internet  browser  at  https://home.shelly.
cloud/. Shelly® devices can be accessed, controlled and monitored 
remotely from any place where the user has internet connectivity, 
as long as the devices are connected to a Wi-Fi router and the Inter-
net. Shelly® devices have Embedded Web Interface accessible at 
http://192.168.33.1 when connected directly to the device access 
point, or at the device IP address on the local Wi-Fi network. The 
embedded Web Interface can be used to monitor and control the 
device, as well as adjust its settings.
Shelly® devices can communicate directly with other Wi-Fi devic-
es through HTTP protocol. An API is provided by Allterco Robotics 
EOOD. For more information, please visit: 
https://shelly-api-docs.shelly.cloud/#shelly-family-overview.
Shelly®  devices  are  delivered  with  factory-installed  rmware.  If 
rmware updates are necessary to keep the devices in conformity, 
including security updates, Allterco Robotics EOOD will provide the 
updates free of charge through the device Embedded Web Inter-
face or the Shelly mobile application, where the information about 
the current rmware version is available.  The choice to install or 
not the  device rmware updates is the user’s sole responsibility. 
Allterco Robotics EOOD shall not be liable for any lack of conformi-
ty of the device caused by failure of the user to install the provided 
updates in a timely manner.
Shelly® Pro Series
Shelly® Pro series is a line of devices suitable for homes, ofces, 
retail stores, manufacturing facilities, and other buildings. Shelly® 
Pro devices are DIN mountable inside the breaker box, and highly 
suitable for new building construction. All Shelly® Pro devices can 
be controlled and monitored through Wi-Fi and LAN connections. 
Bluetooth connection can be used for the inclusion process.
Shelly Pro 3EM (The Device) is a DIN rail mountable three-phase 
energy meter. The Device reports accumulated energy as well as 
voltage, current, power  factor  data  in  real  time. It stores  data  in 
non-volatile  memory for  later  retrieval  at  least  60  days  of  1  min 
data resolution.
Schematic
Fig. 1
Legend
Device terminals:
• A: Phase A input
• B: Phase B input
• C: Phase C and Device power supply input
• N: Neutral input
• IA: Phase A current transformer (CTA) input
• IB: Phase B current transformer (CTB) input
• IC: Phase C current transformer (CTC) input
• IN: Neutral current transformer (CTN) input
Cables:
• LA: Phase A (110-240 VAC)
• LB: Phase B (110-240 VAC)
• LC: Phase C (110-240 VAC)
• N: Neutral cable
Installation Instructions
⚠CAUTION! Danger of electrocution. Mounting/installation of the 
Device to the power grid has to be performed with caution, by a qual-
ied electrician.
⚠CAUTION! Danger of electrocution. Every change in the connec
-
tions has to be done after ensuring there is no voltage present at 
the Device terminals.
⚠CAUTION! Use the Device only with a power grid and appliances 
which comply with all applicable regulations. A short circuit in the 
power grid or any appliance connected to the Device may damage it.
⚠CAUTION!  Do not connect the Device to appliances exceeding 
the given max load!
⚠CAUTION! Connect the Device only  in the way shown in these 
instructions. Any other method could cause damage and/or injury.
⚠CAUTION! Do not install the Device where it can get wet.
⚠CAUTION!  Plug  in or  unplug  the  LAN  cable only  when  the De
-
vice is powered off! The LAN cable must not be metallic in the parts 
touched by the user to plug it in or unplug it.
⚠RECOMMENDATION: Connect the Device using solid single-core 
cables with increased insulation heat resistance not less than PVC 
T105°C (221°F).
Before starting the mounting/installation of the Device, check that 
the breakers are turned off and there is no voltage on their termi-
nals. This can be done with a phase tester or multimeter. When you 
are sure that there is no voltage, you can proceed to connecting 
the cables.
Following the diagram on g. 1 install the current transformer CTA 
around the Phase  A  cable to  the load(s), CTB  around the Phase 
B cable to the load(s) and CTC around the Phase C cable to the 
load(s). Install the CTN around the Neutral cable from your load(s).
Mount the Device onto the DIN rail.
Plug the cables of the CTA, CTB and CTC into the Device IA, IB and 
IC input connectors respectively. Plug the CTN cable into IN. 
Mount circuit breakers in accordance with your local regulations 
IT
GUIDA ALL'USO E ALLA SICUREZZA
SHELLY PRO 3EM
CONTATORE DI ENERGIA TRIFASE
Leggere prima dell'uso
Questo  documento  contiene  importanti  informazioni tecniche  e 
di sicurezza sul dispositivo e sul suo uso e installazione in sicu-
rezza.
⚠ATTENZIONE!  Prima  di  iniziare  l’installazione  leggere  attenta-
mente  e completamente la  documentazione  allegata. La mancata 
osservanza delle procedure consigliate potrebbe portare a malfun-
zionamenti,  pericolo  per  la  vita  o  violazione  della  legge.  Allterco 
Robotics EOOD non è responsabile per eventuali perdite o danni in 
caso di installazione o funzionamento errati di questo dispositivo.
Introduzione al prodotto
Shelly®  è  una  linea  di  dispositivi  innovativi  gestiti  da  micropro-
cessori che permettono il controllo remoto degli elettrodomestici 
attraverso un telefono cellulare, un tablet, un PC o un sistema do-
motico. I dispositivi Shelly® sono in grado di funzionare autono-
mamente in una rete Wi-Fi locale o possono anche essere gestiti 
attraverso servizi di automazione domestica cloud. Shelly Cloud è 
un servizio di questo tipo a cui si può accedere utilizzando un'appli-
cazione mobile Android o iOS o con qualsiasi browser internet su 
https://home.shelly.cloud/.  I dispositivi Shelly® sono accessibili, 
controllati e monitorati a distanza da qualsiasi luogo in cui l'utente 
abbia una connettività Internet, purché i dispositivi siano collegati 
a un router Wi-Fi e a Internet. I dispositivi Shelly® hanno un'inter-
faccia web incorporata accessibile a http://192.168.33.1 nella rete 
Wi Fi, creata dal dispositivo in modalità Access Point, o all'indirizzo 
URL del dispositivo nella rete Wi-Fi a cui è connesso. L'interfaccia 
web incorporata può essere utilizzata per monitorare e controllare 
il dispositivo, così come per regolare le sue impostazioni.
I dispositivi Shelly® sono in grado di comunicare direttamente con 
altri dispositivi Wi-Fi attraverso il protocollo HTTP. Un'API è fornita 
da Allterco Robotics EOOD. Per maggiori informazioni, visitare:
https://shelly-api-docs.shelly.cloud/#shelly-family-overview.
I dispositivi Shelly® vengono consegnati con un rmware installa-
to in fabbrica. Se sono necessari aggiornamenti del rmware per 
mantenere i dispositivi in conformità, compresi gli aggiornamenti 
di sicurezza, Allterco Robotics EOOD fornirà gli aggiornamenti gra-
tuitamente attraverso l'interfaccia web incorporata del dispositivo 
o  l'applicazione  mobile  Shelly,  dove  sono  disponibili  le  informa-
zioni sulla versione corrente del rmware. La scelta di installare o 
meno gli aggiornamenti del rmware del dispositivo è di esclusiva 
responsabilità dell'utente. Allterco Robotics EOOD non è responsa-
bile per qualsiasi mancanza di conformità del dispositivo causata 
dalla mancata installazione degli aggiornamenti forniti dall'utente 
in modo tempestivo.
Shelly® Pro Series
La serie Shelly® Pro è una linea di dispositivi adatti per abitazioni, 
ufci, negozi al dettaglio, impianti di produzione e altri edici. I di-
spositivi Shelly® Pro sono montabili DIN all'interno  della scatola 
dell'interruttore e sono particolarmente adatti per la costruzione di 
nuovi edici. La connettività per tutti i dispositivi Shelly®  Pro può 
avvenire tramite connessione  Internet Wi-Fi o LAN e  il Bluetooth 
può essere utilizzato per il processo di inclusione.
Shelly  Pro  3EM  (Il  Dispositivo)  è  un  contatore  di  energia  trifase 
montabile su guida DIN. Il Dispositivo segnala in tempo reale l'e-
nergia accumulata e i dati relativi alla tensione, corrente e fattore 
di potenza. Il Dispositivo memorizza i dati in memoria non volatile 
per un successivo recupero di almeno 60 giorni di risoluzione dei 
dati di un minuto.
Schema
g.1
Legenda
Terminali del dispositivo:
• A: Ingresso fase A
• B: Ingresso fase B
• C: Ingresso Fase C e alimentazione Dispositivo
• N: Ingresso neutro
• IA: Ingresso trasformatore di corrente (CTA) fase A
• IB: Ingresso trasformatore di corrente (CTB) fase B
• IC: Ingresso trasformatore di corrente (CTC) fase C
• IN: ingresso trasformatore di corrente neutro (CTN)
Cavi:
• LA: Fase A (110-240 VAC)
• LB: Fase B (110-240 VAC)
• LC: Fase C (110-240 VAC)
• N: Cavo neutro
Istruzioni per l'installazione
⚠ATTENZIONE! Pericolo di folgorazione. Il montaggio/installazio-
ne del dispositivo alla rete elettrica deve essere eseguito con cautela 
da un elettricista qualicato.
⚠ATTENZIONE! Pericolo di folgorazione. Ogni  modica dei colle
-
gamenti deve essere effettuata dopo essersi assicurati che non ci 
sia tensione ai morsetti dell'apparecchio.
⚠ATTENZIONE! Utilizzare l'apparecchio solo con una rete elettrica 
e con apparecchi conformi a tutte le norme vigenti. Un cortocircuito 
nella rete elettrica o in qualsiasi apparecchio collegato all'apparec-
chio può danneggiare l'apparecchio.
⚠ATTENZIONE!  Non  collegare  l'apparecchio  ad  apparecchi  che 
superano il carico massimo indicato!
⚠ATTENZIONE!  Collegare  l'apparecchio  solo  nel  modo  indicato 
in queste istruzioni. Qualsiasi altro metodo potrebbe causare danni 
e/o lesioni.
⚠ATTENZIONE! Non installare il dispositivo in un luogo che possa 
bagnarsi.
⚠ATTENZIONE! Collegare o scollegare il cavo  LAN solo quando 
il dispositivo è spento! Il cavo LAN non deve essere metallico nelle 
parti toccate dall'utente per collegare o scollegare il cavo.
⚠RACCOMANDAZIONE  Collegare  il  dispositivo  utilizzando  cavi 
unipolari solidi con una maggiore resistenza termica dell'isolamento 
non inferiore a PVC T105°C.
Prima di iniziare l'installazione/montaggio del dispositivo, control-
lare che gli interruttori siano spenti e che non ci sia tensione sui 
loro terminali. Questo può essere fatto con un misuratore di fase 
o un multimetro. Quando siete sicuri che non c'è tensione, potete 
procedere al collegamento dei cavi.
DE
BENUTZER- UND SICHERHEITSHANDBUCH
SHELLY PRO 3EM
DREIPHASEN-ENERGIEZÄHLER
Bitte vor Gebrauch durchlesen
Dieses  Dokument  enthält  wichtige  technische  und  sicherheits-
technische Informationen über das Gerät und seine sichere Ver-
wendung und Installation.
⚠ACHTUNG!  Bevor  Sie  mit  der  Installation  beginnen,  lesen  Sie 
bitte die Begleitdokumentation sorgfältig und vollständig durch. Die 
Nichtbeachtung der empfohlenen Verfahren kann zu Fehlfunktionen, 
Lebensgefahr  oder  Gesetzesverstößen  führen.  Allterco  Robotics 
EOOD haftet nicht für Verluste oder Schäden im Falle einer falschen 
Installation oder Bedienung dieses Geräts.
Produktvorstellung
Shelly® ist eine Produktserie innovativer, mikroprozessorgesteuer-
ter Geräte, welche die Fernsteuerung von Elektrogeräten über ein 
Mobiltelefon, ein Tablet, einen PC oder ein Hausautomatisierungs-
system ermöglichen. Shelly® Geräte können eigenständig in einem 
lokalen WLAN-Netzwerk arbeiten oder sie können auch über Cloud-
Dienste  für  die  Hausautomatisierung  betrieben  werden.  Shelly 
Cloud ist ein solcher Dienst, auf den entweder über eine Android- 
oder  iOS-Applikation  oder  über  einen  beliebigen  Internetbrowser 
unter https://home.shelly.cloud/ zugegriffen werden kann. Shelly® 
Geräte können von jedem Ort aus, an dem der Benutzer eine Inter-
netverbindung hat, angesprochen,  gesteuert  und  überwacht  wer-
den, solange die Geräte mit einem WLAN-Router und dem Internet 
verbunden sind. Shelly® Geräte verfügen über eine integrierte Web-
Schnittstelle, die unter http://192.168.33.1 im WLAN-Netzwerk zu-
gänglich ist, das vom Gerät im Access Point-Modus erstellt wird, 
oder  unter  der  IP-Adresse  des  Gerätes  im  WLAN-Netzwerk,  mit 
dem es verbunden ist. Die integrierte Web-Schnittstelle kann zur 
Überwachung  und  Steuerung  des  Gerätes  sowie  zur  Anpassung 
dessen Einstellungen verwendet werden.
Shelly® Geräte können direkt mit anderen WLAN-Geräten über das 
HTTP-Protokoll kommunizieren. Eine API wird von Allterco Robo-
tics EOOD bereitgestellt. Für weitere Informationen besuchen Sie 
bitte: 
https://shelly-api-docs.shelly.cloud/#shelly-family-overview
.
Shelly®  Geräte werden mit werkseitig installierter Firmware aus-
geliefert. Um die Geräte konform zu halten, stellt Allterco Robotics 
EOOD  die  notwendigen  Firmware-Updates,  einschließlich  der  Si-
cherheitsupdates, kostenlos über die im Gerät eingebettete Web-
Schnittstelle  sowie  über  die  Shelly-App  zur  Verfügung.  Die  Ent-
scheidung, die Firmware-Updates des Geräts zu installieren oder 
nicht, obliegt der alleinigen Verantwortung des Benutzers. Allterco 
Robotics  EOOD  haftet  nicht  für  Konformitätsmängel  des  Geräts, 
die  darauf  zurückzuführen  sind,  dass  der  Benutzer  die  bereitge-
stellten Updates nicht rechtzeitig installiert hat.
Shelly® Pro-Serie
Die  Shelly®  Pro-Serie  ist  eine  Produktserie,  die  für  Wohnungen, 
Büros, Einzelhandelsgeschäfte, Produktionsstätten und andere Ge-
bäude geeignet ist. Sie sind auf der DIN-Schiene im Stromkasten 
montierbar  und  sehr  gut  für  den  Neubau  geeignet.  Alle  Shelly® 
Pro-Geräte  können  sowohl  über  eine  WLAN-  als  auch  über  eine 
LAN-Verbindung gesteuert und überwacht werden. Bluetooth kann 
zusätzlich für die Einbindung genutzt werden.
Shelly Pro 3EM (das Gerät) ist ein dreiphasiger Energiezähler für 
die  DIN-Schienenmontage.  Das  Gerät  meldet  die  akkumulierte 
Energie sowie die Daten zu Spannung, Strom und Leistungsfaktor 
in Echtzeit. Es speichert die Daten in einem internen Speicher für 
den späteren Abruf von mindestens 60 Tagen mit einer Datenauf-
lösung von 1 Minute.
Schematische Darstellung
Abb. 1
Legende
Geräteanschlüsse:
• A: Eingang Phase A
• B: Eingang Phase B
• C: Eingang Phase C und Gerätestromversorgung
• N: Eingang Neutralleiter
• IA: Eingang Stromwandler (CTA) für Phase A
• IB: Eingang Stromwandler (CTA) für Phase B
• IC: Eingang Stromwandler (CTA) für Phase C
• IN: Eingang Stromwandler (CTN) für Neutralleiter
Kabel:
• LA: Phase A (110-240 VAC)
• LB: Phase B (110-240 VAC)
• LC: Phase C (110-240 VAC)
• N: Neutralleiter
Installationsanleitung
⚠VORSICHT!  Gefahr  eines  Stromschlages.  Die  Montage/Instal-
lation des  Geräts an das Stromnetz muss von einem qualizierten 
Elektriker mit Vorsicht durchgeführt werden!
⚠VORSICHT! Es besteht Stromschlaggefahr.  Bei jeder Änderung 
der Anschlüsse muss sichergestellt werden, dass an den Klemmen 
des Geräts keine Spannung anliegt!
⚠VORSICHT! Verwenden Sie das Gerät nur mit einem Stromnetz 
und Geräten, die allen geltenden Vorschriften entsprechen. Ein Kurz-
schluss im Stromnetz oder in einem an das Gerät angeschlossenen 
Gerätes kann dieses beschädigen!
⚠VORSICHT! Schließen Sie das Gerät nicht an Geräte an, die die 
angegebene Höchstlast überschreiten!
⚠VORSICHT! Schließen Sie das Gerät nur auf die in dieser Anlei-
tung beschriebene Weise an. Jede andere Methode kann zu Schä-
den und/oder Verletzungen führen!
⚠VORSICHT! Installieren Sie das Gerät nicht an einem Ort, an dem 
es nass werden kann!
⚠VORSICHT! Das LAN-Kabel nur bei ausgeschaltetem Gerät ein- 
oder ausstecken! Das LAN-Kabel darf an den Stellen, an denen es 
beim Ein- oder Ausstecken berührt wird, nicht metallisch sein!
⚠EMPFEHLUNG: Schließen Sie das Gerät mit massiven einadrigen 
Kabeln mit erhöhter Isolationswärmebeständigkeit von mindestens 
PVC T105°C an!
Bevor Sie mit der Installation/Montage des Geräts beginnen, prü-
fen Sie, ob die Leitungsschutzschalter (Sicherungen) ausgeschal-
tet sind und keine Spannung an den Klemmen anliegt. Dies kann 
mit einem Phasenprüfer oder Multimeter erfolgen. Wenn Sie sicher 
sind, dass keine Spannung anliegt, können Sie mit dem Anschluss 
and connect the Phase  A, Phase  B  and Phase  C cables  through 
them to the Device A, B and C inputs respectively. Connect the Neu-
tral cable to the N input.
The Device is powered through its C input.
Make sure you have made all the connections correctly and then 
turn on the circuit breakers.
Initial Inclusion
If you choose to use the Device with the Shelly Cloud mobile appli-
cation and Shelly Cloud service, instructions on how to connect the 
Device to the Cloud and control it through the Shelly App can be 
found in the “App Guide”. The Shelly mobile application and Shelly 
Cloud  service  are  not    not  conditions  for  the  Device  to  function 
properly. This Device can be used standalone or with various other 
home automation platforms and protocols.
⚠CAUTION! Do not allow children to play with the buttons/switch-
es connected to the Device. Keep the devices for remote control of 
Shelly (mobile phones, tablets, PCs) away from children.
LED indication
• Power: Red light if power supply is connected.
• Wi-Fi (varies):
 - Blue light if in AP mode
 - Red light if in STA mode, and not connected to a Wi-Fi network
 - Yellow light if in STA mode, and connected to a Wi-Fi network. 
Not connected to Shelly Cloud or Shelly Cloud disabled
 - Green light if in STA mode, and connected to a Wi-Fi network 
and the Shelly Cloud
 -The LED will be ashing Red/Blue if OTA update is in progress
• LAN: Green light if LAN is connected.
• Count: Red light will be ashing when the Device is measuring 
energy  according to settings with frequency  dependent to the 
energy owing through the measured circuit.
User button
• Press and hold for 5 sec to activate Device AP
• Press and hold for 10 sec to factory reset
Specication
• Dimensions (HxWxD): 94x19x69 mm / 3.70x0.75x2.71 in
• Mounting: DIN rail
• Ambient temperature: from -20 °C to 40 °C / from -5 °F to 105 °F
• Humidity 30 % to 70 % RH
• Max. altitude 2000 m / 6562 ft
• Power supply: 110 - 240 VAC, 50/60Hz
• Electrical consumption: < 3 W
• Internal temperature sensor: Yes
• Voltmeters (RMS for each phase): 100 - 260 V
• Voltmeters accuracy: ±1 %
• Ammeters (RMS via CT for each phase and the Neutral): 0 - 120 A
• Ammeters accuracy:
 - ±1 % (2 - 120 A)
 - ±2 % (1 - 2 A)
 - ±5 % (0 - 1 A)
• Phase sequence error detection: Yes (option)
• Power and energy meters:
 - Active and apparent power
 - Active and apparent energy
 - Power factor
 - Fundamental active and fundamental reactive energy
• Measurement data storage: At least 60 days of 1 min data res-
olution
• Data export:
 - CSV for PQ recorded values
 - JSON format export through RPC
• Wi-Fi protocol: 802.11 b/g/n
• Wi-Fi frequency: 2412 - 2472 МHz (Max. 2483 MHz)
• Wi-Fi max. RF output power: 15 dBm
• Wi-Fi operational range (depending on local conditions):
 - up to 50 m / 160 ft outdoors
 - up to 30 m / 100 ft indoors
• Bluetooth protocol: BLE 4.1
• Bluetooth frequency: 2402 - 2480 MHz (Max. 2483.5 MHz)
• Bluetooth operational range (depending on local construction):
 - up to 30 m / 100 ft outdoors,
 - up to 10 m / 33 ft indoors
• Bluetooth max. RF output power: 5 dBm
• CPU: ESP32
• Flash: 16 MB
• Webhooks (URL actions): 20 with 5 URLs per hook
• Scripting: mJS
• MQTT: Yes
Declaration of conformity
Hereby, Allterco Robotics EOOD declares that the radio equipment 
type Shelly Pro 3EM is in compliance with Directive 2014/53/EU, 
2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the EU dec-
laration of conformity is available at the following internet address:
https://shelly.cloud/knowledge-base/devices/shelly-pro-3em/
Manufacturer: Allterco Robotics EOOD
Address: 103 Cherni vrah Blvd., 1407 Soa, Bulgaria
Tel.: +359 2 988 7435
E-mail: support@shelly.cloud
Ofcial website: https://www.shelly.cloud
Changes in the contact information data are published by the Man-
ufacturer on the ofcial website.
https://www.shelly.cloud
All rights to the trademark Shelly® and other intellectual rights as-
sociated with this Device belong to Allterco Robotics EOOD.
Seguendo lo schema in g. 1 installare il trasformatore di corren
-
te CTA attorno al cavo di Fase A al carico/carichi, CTB attorno al 
cavo di Fase B al carico/carichi e CTC attorno al cavo di Fase C 
al carico/carichi.
Installare il CTN attorno al cavo Neutro dal carico/carichi.
Montare il Dispositivo sulla barra DIN.
Collegare i cavi del CTA, CTB e CTC rispettivamente ai connettori 
di ingresso IA, IB e IC del Dispositivo. Inserire il cavo CTN in IN.
Montare gli interruttori automatici in conformità con le normative 
locali e collegare i cavi di Fase A, Fase B e Fase C attraverso di essi 
rispettivamente agli ingressi del Dispositivo A, B e C. Collegare il 
cavo Neutro all'ingresso N.
Il Dispositivo è alimentato attraverso il suo ingresso C.
Assicurarsi di aver effettuato correttamente tutti i collegamenti e 
quindi accendere gli interruttori automatici.
Inclusione iniziale
Se  si  sceglie  di utilizzare il dispositivo con l'applicazione mobile 
Shelly Cloud e il servizio Shelly Cloud, le istruzioni su come colle-
gare il dispositivo al Cloud e controllarlo attraverso l'App Shelly si 
trovano nella "Guida App". L'applicazione mobile Shelly e il servizio 
Shelly Cloud non sono condizioni per il corretto funzionamento del 
Dispositivo. Questo Dispositivo può essere utilizzato con vari altri 
servizi e applicazioni di automazione domestica.
⚠ATTENZIONE! Non  permettere ai bambini  di giocare  con i pul-
santi/interruttori  collegati  al Dispositivo. Tenere  i dispositivi per  il 
controllo remoto di Shelly (telefoni cellulari, tablet, PC) lontano dai 
bambini.
Indicazione dei LED
• Power: Luce rossa se l'alimentazione è collegata.
• Wi-Fi (varia):
 - Luce blu se in modalità AP
 - Luce rossa se in modalità STA, e non collegato a una rete Wi-Fi
 - Luce gialla se in modalità STA, e collegato a una rete Wi-Fi. Non 
connesso a Shelly Cloud o Shelly Cloud disattivato
 - Luce verde se in modalità STA, e connesso a una rete Wi-Fi e 
a Shelly Cloud
 - Il LED lampeggerà in Rosso/Blu se l'aggiornamento OTA è in 
corso
• LAN: Luce verde se la LAN è connessa.
• Count: La luce rossa  lampeggerà  quando  il Dispositivo  misura 
l'energia  in  base  alle  impostazioni  con  frequenza  dipendente 
dall'energia che uisce attraverso il circuito misurato.
Pulsante utente
• Tenere premuto per 5 secondi per attivare l'AP del Dispositivo
• Tenere premuto per 10 secondi no al reimpostazione di fabbrica
Speciche
• Dimensioni (AxLxP): 94x19x69 mm / 3.70x0.75x2.71 in
• Montaggio: Guida DIN
• Temperatura ambiente: da -20 °C a 40 °C / da -5 °F a 105 °F
• Umidità Dal 30 % al 70 % di umidità relativa
• Altitudine massima: 2000 m / 6562 ft
• Alimentazione: 100 - 260 VAC, 50/60Hz
• Consumo elettrico: < 3 W
• Sensore di temperatura interna: Sì
• Voltmetri (RMS per ogni fase): 100 - 260 V
• Precisione dei voltmetri: ±1 %
• Amperometri (RMS via CT per ogni fase e il Neutro): 0 - 120 A
• Precisione degli amperometri:
 - ±1 % (2 - 120 A)
 - ±2 % (1 - 2 A)
 - ±5 % (0 - 1 A)
• Rilevamento errore sequenza fasi: Sì (opzione)
• Contatori di potenza ed energia:
 - Alimentazione attiva e apparente
 - Energia attiva e apparente
 - Fattore potenza
 - Energia reattiva fondamentale attiva e fondamentale
• Archiviazione dei dati di misurazione: 60 giorni con risoluzione 
dei dati di 1 minuto
• Esportazione dati:
 - CSV per valori registrati PQ
 - Esportazione formato JSON tramite RPC
• Protocollo Wi-Fi: 802.11 b/g/n
• Wi-Fi frequenza: 2412 - 2472 МHz (max. 2483 MHz)
• Potenza massima in uscita RF Wi-Fi: 15 dBm
• Intervallo operativo Wi-Fi (a seconda delle condizioni locali):
 -no a 50 m / 160 ft all'aperto
 -no a 30 m / 100 ft all'interno
• Protocollo Bluetooth: BLE 4.1
• Bluetooth frequenza: 2402 - 2480 MHz (Max. 2483.5 MHz)
• Bluetooth portata operativa (a seconda della struttura locale):
 -no a 30 m / 100 ft all'aperto,
 -no a 10 m / 33 ft all'interno
• Potenza massima in uscita RF Bluetooth: 5 dBm
• CPU: ESP32
• Flash: 16 MB
• Webhook (azioni URL): 20 con 5 URL per ogni hook
• Scripting: mJS
• MQTT: SÌ
Dichiarazione di conformità
Con  la  presente,  Allterco  Robotics  EOOD  dichiara  che  il  tipo  di 
apparecchiatura  radio  Shelly  Pro  3EM  è  conforme  alla  Direttiva 
2014/53/UE, 2014/35/UE, 2014/30/UE, 2011/65/UE. Il testo com-
pleto della dichiarazione di conformità UE è disponibile al seguente 
indirizzo internet
https://shelly.cloud/knowledge-base/devices/shelly-pro-3em/
Produttore: Allterco Robotics EOOD
Indirizzo: Bulgaria, Soa, 1407, 103 Cherni vrah Blvd.
Tel.: +359 2 988 7435
E-mail: support@shelly.cloud
Sito web ufciale:https://www.shelly.cloud
Le modiche ai dati di contatto sono pubblicate dal Produttore sul 
sito Web ufciale.
https://www.shelly.cloud
Tutti i diritti sul marchio Shelly® e altri diritti intellettuali associati a 
questo dispositivo appartengono a Allterco Robotics EOOD.
der Kabel fortfahren!
Nach dem Schema in Abb. 1 installieren Sie den Stromwandler CTA 
um das Kabel der Phase A zu dem/den Verbraucher(n), CTB um 
das Kabel der  Phase B zu dem/den Verbraucher(n) und CTC um 
das Kabel der Phase C zu dem/den Verbraucher(n). Installieren Sie 
den CTN um das Neutralleiterkabel von Ihrem(n) Verbraucher(n).
Montieren Sie das Gerät auf der DIN-Schiene.
Stecken  Sie  die Kabel  von  CTA, CTB  und  CTC  jeweils  in  die Ein-
gangsanschlüsse von Device IA, IB und IC. Stecken Sie das CTN-
Kabel in IN. 
Montieren Sie die Schutzschalter gemäß den örtlichen Vorschriften 
und verbinden Sie die Kabel der Phasen A, B und C über diese mit 
den Eingängen A, B und C des Geräts. Verbinden Sie das Neutral-
leiterkabel mit dem Eingang N.
Das Gerät wird über den C-Eingang mit Strom versorgt.
Vergewissern  Sie  sich,  dass Sie alle Verbindungen richtig herge-
stellt haben, und schalten Sie dann die Schutzschalter ein.
Erstmalige Einbindung
Wenn Sie sich dafür entscheiden, das Gerät mit der Shelly Cloud 
App und dem Shelly Cloud Service zu verwenden, nden Sie Anwei-
sungen zur Verbindung des Geräts mit der Cloud und zur Steuerung 
über die Shelly App im “App Guide”. Die Shelly Mobile App und der 
Shelly Cloud Service sind keine Voraussetzung für das ordnungs-
gemäße Funktionieren des Geräts. Dieses Gerät kann alleine, sowie 
mit  verschiedenen  anderen  Hausautomatisierungsdiensten  und 
-anwendungen verwendet werden.
⚠VORSICHT! Erlauben Sie Kindern nicht, mit den an das Gerät an
-
geschlossenen Tasten/Schaltern zu spielen. Halten Sie die Geräte 
zur Fernsteuerung des Shelly (z.B.: Mobiltelefone, Tablets, PCs) von 
Kindern fern.
LED-Anzeige
• Power:  Rotes Licht, wenn die Stromversorgung angeschlossen 
ist.
• Wi-Fi (variiert):
 - Blaues Licht wenn in AP Modus
 - Rotes  Licht  wenn  in  STA  Modus,  aber  nicht  mit  dem  WLAN 
verbunden
 - Gelbes Licht wenn in STA mode, Verbunden mit WLAN-Netz-
werk. Nicht verbunden mit der Shelly Cloud oder Shelly Cloud 
deaktiviert 
 - -Grünes Licht wenn in STA mode, Verbunden mit WLAN-Netz
werk und der Shelly Cloud 
 - Rot/Blau blinkendes Licht wenn OTA-Update läuft
• LAN: Grünes Licht, wenn das LAN verbunden ist.
• Count:  Das  rote  Licht  blinkt,  wenn  das  Gerät  die  Energie  ent-
sprechend den Einstellungen misst, wobei die Häugkeit von der 
Energie abhängt, die durch den gemessenen Stromkreis ießt.
Benutzertaste
5 Sekunden lang gedrückt halten, um den AP zu aktivieren 10 Se-
kunden lang gedrückt halten, um auf Werkseinstellungen zurück-
zusetzen
Spezikation
• Abmessungen (HxBxT): 94x19x69 mm / 3.70x0.75x2.71 in
• Montage: DIN-Schiene
• Umgebungstemperatur: -20 °C bis 40 °C / -5 °F bis 105 °F
• Luftfeuchtigkeit 30 % bis 70 % RH
• Max. Höhe ü.M.: 2000m / 6562 ft
• Spannungsversorgung: 100 - 260 VAC, 50/60Hz
• Elektrischer Verbrauch: < 3 W
• Interner Temperatursensor: Ja
• Voltmeter (RMS für jede Phase): 100 - 260 V
• Voltmeter Genauigkeit: ±1 %
• Strommessgeräte (RMS über Stromwandler für jede Phase und 
Neutralleiter): 0 - 120 A
• Genauigkeit des Amperemeters:
 - ±1 % (2 - 120 A)
 - ±2 % (1 - 2 A)
 - ±5 % (0 - 1 A)
• Erkennung von Phasensequenzfehlern: Ja (Option)
• Leistungs- und Energiezähler:
 - Wirk- und Scheinleistung
 - Wirk- und Scheinenergie
 - Leistungsfaktor
 - Grundlegende Wirk- und Blindenergie
• Speicherung der Messdaten: Mindestens 60 Tage mit einer Da-
tenauösung von 1 Minute
• Datenexport:
 - CSV für aufgezeichnete PQ-Werte
 - Export im JSON-Format über RPC
• WLAN-Protokoll: 802.11 b/g/n
• WLAN Frequenz: 2412 - 2472 МHz (Max. 2483 MHz)
• WLAN max. RF-Ausgangsleistung: 15 dBm
• WLAN-Reichweite (abhängig von den örtlichen Gegebenheiten):
 - bis zu 50 m / 160 ft im Freien
 - bis zu 30 m / 100 ft in Innenräumen
• Bluetooth-Protokoll: BLE 4.1
• Bluetooth Frequenz: 2402 - 2480 MHz (Max. 2483.5 MHz)
• Bluetooth  Reichweite  (abhängig  von  den  baulichen  Gegeben-
heiten):
 - - bis zu 30 m / 100 ft im Freien,
 - - bis zu 10 m / 33 ft in Innenräumen
• Bluetooth max. RF-Ausgangsleistung: 5 dBm
• CPU: ESP32
• Flash: 16 MB
• WebHooks (URL-Aktionen): 20 mit 5 URLs pro WebHook
• Skripting: mJS
• MQTT: Ja
Konformitätserklärung
Hiermit erklärt Allterco Robotics EOOD, dass der Funkanlagentyp 
Shelly PRO 3EM der Richtlinie 2014/53/EU, 2014/35/EU, 2014/30/
EU, 2011/65/EU entspricht. Den vollständigen Text der EU-Konfor-
mitätserklärung nden Sie unter folgender Internetadresse
https://shelly.cloud/knowledge-base/devices/shelly-pro-3em/
Hersteller: Allterco Robotics EOOD
Adresse: 103 Cherni vrah Blvd., 1407 Soa, Bulgarien
Tel.: +359 2 988 7435
E-Mail: support@shelly.cloud
Ofzielle Website: https://www.shelly.cloud
Änderungen der Kontaktdaten werden vom Hersteller auf dessen 
ofziellen Website veröffentlicht
https://www.shelly.cloud
Alle  Rechte  an  der  Marke  Shelly®  und  anderen  geistigen  Eigen-
tumsrechten im Zusammenhang mit diesem Gerät gehören Allter-
co Robotics EOOD.
48/2022
Specyfikacje produktu
| Marka: | Shelly | 
| Kategoria: | inteligentny dom | 
| Model: | Pro 3EM | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Shelly Pro 3EM, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje inteligentny dom Shelly
                        
                         27 Marca 2025
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         22 Września 2024
                        
                    
                                                            
                        
                         22 Września 2024
                        
                    
                                                            
                        
                         22 Września 2024
                        
                    
                                                            
                        
                         22 Września 2024
                        
                    
                                                            
                        
                         21 Września 2024
                        
                    
                                                            
                        
                         21 Września 2024
                        
                    
                                                            Instrukcje inteligentny dom
- Crestron
- Intertechno
- Niceboy
- V-TAC
- Edimax
- Nobo
- Bose
- Salus
- Byron
- Inkbird
- Logicom
- Hive
- Casambi
- TP-Link
- Tesla
Najnowsze instrukcje dla inteligentny dom
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         18 Marca 2025
                        
                    
                                                            
                        
                         18 Marca 2025
                        
                    
                                                            
                        
                         12 Marca 2025
                        
                    
                                                            
                        
                         25 Lutego 2025
                        
                    
                                                            
                        
                         19 Lutego 2025
                        
                    
                                                            
                        
                         14 Lutego 2025
                        
                    
                                                            
                        
                         30 Stycznia 2025