Strona 1/16

Operating Instructions
PROFITEST⏐PRCD
Adapter for Standards Compliant Testing of PRCDs
by Simulating Faults 3-349-797-15
7/4.19
Important
Read carefully before use!
Keep on file for future reference!
Please observe the manufacturer‘s details
on the devices under test!

2 GMC-I Messtechnik GmbH
Connections Overview
1 Coupling plug to the outlet of a
3-phase PRCD
2 Earthing contact plug to the outlet of a
single-phase PRCD
3 Probe socket for contacting the on/off
key on the PRCD
4 Earthing contact socket to the inlet of a
single-phase PRCD
5 Loop for measuring protective conductor
current with a current clamp transformer
6 CEE socket to the inlet of a 3-phase
PRCD
7 Mains power cable with earthing contact plug
8 3-phase mains power cable with
CEE outlet (1P+N+PE 16 A-6h)
9 PRCD inlet sockets connected in parallel
to sockets 4 and 6 – for connecting the
PROFITEST MXTRA during protective con-
ductor and insulation measurements
10 PRCD outlet sockets connected in paral-
lel to plugs 1 and 2 for connecting the
PROFITEST MXTRA during protective con-
ductor and insulation measurements
11 Five replaceable fuses
Instrument Overview
8
7
6
4
1
2
10
3
9
Mains Connection
To PRCD Outlet
To PRCD Inlet ( )PRCD IN
5
11
( )PRCD OUT
Fault Selection Mains disconnect, 1~OFF/3~OFF
– For RISO measurement
Mains power on, 1~ON/3~ON
– For fault simulation
– For RLO measurement
Phase LEDs
Phase Interrupt
Reversed Wires
Orange positions: testing at single-phase PRCDs
Green positions: testing at 3-phase PRCDs
Mains
– For tripping test with I
Nom
and measurement of time to trip
Connection
PROFITEST⏐PRCD Operating and Connections Overview

GMC-I Messtechnik GmbH 3
Meanings of Symbols on the Instrument
300 V CAT II
Maximum permissible voltage and
measuring category between con-
nections and ground
Warning concerning a point of
danger
(attention:
observe documentation!)
Indicates European Conformity
This device may not be disposed
of with the trash.
Further information regarding the
WEEE mark can be accessed on
the Internet at www.gossenme-
trawatt.com by entering the
search term “WEEE”.
Meanings of Symbols in the Operating Instructions
LED L1, L2, L3, N or PE at test adapter
LED on LED off
PRCD LED at the device under test
LED on LED off
Scope of Delivery
1 Test adapter
1 Probe cable with plug-in test probe
1 Set of operating instructions
Table of Contents Page
1 Safety Precautions .................................... 4
2 Applications .............................................. 5
3 Initial Start-Up ........................................... 6
3.1 Testing the LEDs ......................................... 6
3.2 Mains Connection ....................................... 6
3.3 Connecting the PRCD .................................. 7
4 Measurements with the
PROFITEST MXTRA .................................... 7
4.1
Measuring Protective Conductor Resistance (Rlo) ....... 7
4.2
Measuring Insulation Resistance (Riso) ............. 8
4.3
Tripping Test with Nominal Residual Current and
Measurement of Time to Trip ...............................8
4.4 Varistor Test (PRCD-K) ................................. 9
5 Protective Conductor Current Measurement 9
6 Fault Simulation ...................................... 10
6.1 PRCD-S (single-phase) ............................. 10
6.1.1 Simulated Interruption ....................................... 10
6.1.2 Simulated Wire Reversal .................................... 10
6.1.3 Simulation of PE to Phase – PE-UEXT ................. 10
6.1.4 Contacting the “ON” Key at the PRCD with the Probe......11
6.2 PRCD-K (single-phase) ............................. 11
6.2.1 Simulated Interruption ....................................... 11
6.3 PRCD-S (3-phase) .................................... 12
6.3.1 Simulated Interruption ....................................... 12
6.3.2 Simulated Wire Reversal .................................... 13
6.3.3 Simulation of PE to Phase ................................... 13
7 Characteristic Values .............................. 14
8 Maintenance ........................................... 14
8.1 Housing Maintenance ................................ 14
8.2 Safety Checks – Testing in Compliance with
DGUV Provision 3 ...................................... 15
8.2.1
Testing of Protective Conductor Resistance RPE ............15
8.2.2 Testing of Insulation Resistance: ......................... 15
8.2.3 Contact Current Measurement ............................ 16
8.3 Fuse Replacement ..................................... 16
8.4 Return and Environmentally Sound Disposal 16
9
Repair and Replacement Parts Service, Calibration
Center and Rental Instrument Service ................. 16
10 Product Support ...................................... 16
!
PROFITEST⏐PRCD Symbols – Scope of Delivery – Table of Contents
Specyfikacje produktu
Marka: | Gossen Metrawatt |
Kategoria: | Niesklasyfikowane |
Model: | PROFITEST PRCD M512R |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Gossen Metrawatt PROFITEST PRCD M512R, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Gossen Metrawatt
3 Stycznia 2025
3 Stycznia 2025
3 Stycznia 2025
3 Stycznia 2025
3 Stycznia 2025
31 Grudnia 2025
16 Grudnia 2024
4 Października 2024
3 Października 2024
3 Października 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane KidKraft
- Niesklasyfikowane Clifford
- Niesklasyfikowane Sport-Tronic
- Niesklasyfikowane Ygnis
- Niesklasyfikowane Areca
- Niesklasyfikowane Rolly Toys
- Niesklasyfikowane Sanofi
- Niesklasyfikowane Goal Zero
- Niesklasyfikowane Ganz
- Niesklasyfikowane Generation
- Niesklasyfikowane Crest Audio
- Niesklasyfikowane Tommee Tippee
- Niesklasyfikowane Enbrighten
- Niesklasyfikowane Eurom
- Niesklasyfikowane AXESS
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025