 Operating Instructions
3-447-253-15
1/6.24
© Gossen Metrawatt GmbH
Prepared in Germany • Subject to change, errors 
excepted • A pdf version is available on the Internet
All trademarks, registered trademarks, logos, prod-
uct names, and company names are the property of 
their respective owners.
Gossen Metrawatt GmbH
Südwestpark 15
90449 Nürnberg
Germany
Phone: +49 911 8602-0
Fax: +49 911 8602-669
info@gossenmetrawatt.com
www.gossenmetrawatt.com
METRALINE EVSE IT 
(Z525M)
1-/3-phase  test  adapter  for  testing  the 
effectiveness  of  protective  measures  at 
e-charging points for the METRALINE MF
ranges (as for example medicine and agriculture).
   Measurements  in  dangerous  proximity  of  electrical 
systems are only to be carried out in compliance with 
the  instructions  of  a  responsible  electronics  techni-
cian, and never alone.
   If  the  operator’s  safety  is  no  longer  ensured,  the 
instrument is to be put out of service and protected 
against  use.  The  safety  is  no  longer  insured,  if  the 
instrument
•  shows obvious damage,
•   does not carry out the desired measurements,
•   has  been stored for  too long under  unfavourable 
conditions,
•   has  been  subjected  to  mechanical  stress  during 
transport.
   The instrument may only be used within the operating 
ranges as specied in the technical data section.
   Avoid any heating up of the instrument by direct sun-
light to ensure perfect functioning and long instrument 
life.
   The opening of the instrument for fuse replacement, 
for example, may only be carried out by professionals. 
Prior to opening, the instrument has to be switched off 
and disconnected from any current circuit.
   The instrument may only be used under those condi-
tions and for those purposes for which it was conceived.  
For  this  reason,  in  particular  the  safety  references, 
the technical data including environmental conditions 
and the usage in dry environments must be followed.
When modifying or changing the instrument, the operation-
al safety is no longer ensured.
2  Application
Please read this important information!
2.1  Intended use / Use for intended purpose
The METRALINE EVSE IT is a test adapter (accessory) to 
support all relevant measurements of the METRALINE MF. 
It is connected between the EVSE charging point (Type-2 
connector) and the measurement inputs of the METRALINE 
MF. All wires of the charging connector are available: L1, 
L2, L3, N, PE, CP and PP.
This allows to perform typical measurements: voltage, fre-
quency,  phase  indication,  phase  sequence,  various  RCD 
tests  and  measurements,  insulation  resistance,  low  ohm 
measurements, line and loop impedances, etc.
Safety of the user, as well as that of the instrument, is only 
assured when it’s used for its intended purpose.
2.2  Use for other than intended purpose
Using  the  instrument  for  any  purposes  other  than  those 
described in these instrument operating instructions is con-
trary to use for intended purpose. Use for purposes other 
than those intended may result in unforeseeable damage!
2.3  Liability and guarantee
The warranty  provided  by  Gossen  Metrawatt GmbH, and 
its liability, are governed by the applicable contractual and 
mandatory statutory provisions.
3  Documentation
  DANGER!
   DANGER!  Dangerous  voltage.  Danger  of  electrical 
shock.
  Note! Important information.
4  The instrument
4.1  Scope of delivery
1 METRALINE EVSE IT
1 Operating instructions (this document)
Please check the scope of delivery for completeness and 
intactness.
4.2  Device overview
Operation elements and connectors:
CP Mode:
1.  Type 2 plug
2.  Slider switch for CP mode selection
3.   Test leads with 4 mm safety plugs for L1, L2, L3, N, PE, 
CP and PP
The adapter is equipped with 1.5 m test leads.
1
3
2
4.3  Symbols on the instrument 
   Warning of  a potential  danger. Read and follow  the 
operating instructions.
   Continuous double or reinforced insulation category II 
(IEC 536 / DIN EN 61140).
   Conformity  symbol,  the  instrument  com-
plies with the valid EU directives.    
It complies with the EMC Directive (2014/30/EU), DIN 
EN IEC 61326, the Low Voltage Directive (2014/35/
EU), DIN EN 61010-1 and DIN EN 61010-031.   
You can nd the CE declaration on our website.
   The instrument may not be disposed of with house-
hold trash. You are required to comply with all appli-
cable local regulations. Further information regarding 
disposal can be found on our website.
4.4  Specications
Input voltage:  230 V / 400 V  3~  50 / 60 Hz
Measurement category: CAT II 300 V
Mains socket rating: max. 10 A
PP simulation: internally congured for 32 A
CP simulation: states A, B, C
Error simulation: CP error “E”
Test connectors to test/
measuring instrument:
4 mm safety-plug-in
Test connector type:  IEC 62196-2 Type 2 male
Test cable length: 1.5 m
IP IP40
Working temperature: 0 … +40 ºC
Storage temperature: –10 … +50 ºC
Humidity: 0 … 80 % relative humidity
Compliance with:
 DIN EN 61010-1 /    
DIN EN 61010-031
5  Testing
5.1  Test procedure
1.   Connect the needed 4 mm test leads of the METRALINE 
EVSE IT to your METRALINE MF.
2.   Select CP mode “A” with the slider switch.
3.   Connect METRALINE EVSE IT to the Type 2 connector 
of the charging point.
4.   Select CP mode “B” with the slider switch, the charging 
point should show “ready to charge”.
5.   Select CP mode “C” with the slider switch, the charging 
point starts charging.
6.   Perform  all  measurements  in  active  stage  of  the 
charging point (voltage and similar).   
Refer to the METRALINE MFproduct documentation.
7.   After  you  completed  all  your  measurements  
select  CP  Mode  “A”  with  the  slider  switch  to  stop 
charging.
8.   Unplug METRALINE EVSE IT from the charging point.
5.2  Proximity Pilot (PP) state (cable simulation)
The  METRALINE  EVSE  IT  is  designed  in  such  a  way 
(220 Ω between PP and PE) that it provides a 32 A current 
capability.
5.3  Control Pilot (CP) state (vehicle simulation)
Using the CP mode slider switch, various vehicle states can 
be simulated. Vehicle states are simulated through different 
resistances  connected  between  CP  and  PE  conductors. 
The  correlation  between  resistance  and  vehicle  states  is 
shown in the table below.
Vehicle 
State
State Description CP-PE 
Resistance
CP terminal 
voltage
A Electric vehicle not 
connected
Open (∞) +12 V 
@ 1KHz
B Vehicle connected, 
not ready to charge
2.74 kΩ +9V / –12 V 
@ 1 KHz
C Electric vehicle 
connected, ready to 
charge, ventilation 
not required
882 Ω +6V / –12 V 
@ 1 KHz
[E] CP Error „E“ 
(see below)
0 Ω 0 V
5.4  CP Signal output terminals
The  CP  output  terminals  are  short  connected  to  the  CP 
and PE  conductors  of  the  tested charging station via  the 
test cable. Use an oscilloscope to check the waveform and 
amplitude of the CP signal.
The  Control  Pilot  function  uses  Pulse  Width  Modulation 
(PWM)  to  code  communication  between  a  vehicle  and 
charging station. The duty cycle of the PWM signal denes 
the possible available charging current, while the amplitude 
denes the charger state.
For details of the communication protocol refer to DIN EN 
IEC 61851-1 and the manufacturer’s documentation of the 
charging station.
   If  the  charging  station  is  wired  incorrectly, 
low  signal  CP  test  terminals  may  receive  high, 
life-threatening voltage.
5.5  CP Error “E” simulation
The  “E”-CP  error  simulation  can  be  realized  by  pushing 
the slider switch into (spring loaded) position [E]. This will 
simulate the behaviour of a charging station when there is a 
short circuit between CP and PE through the internal diode 
(acc. to DIN EN IEC 61851-1).
In case of an CP error (“E” is pushed), the expected result 
is an abortion of the charging process and a new charging 
process is prevented.
5.6  Measuring terminals
The measuring terminals (no. 1 and 2 in the device over-
view) are directly connected to the L1, L2, L3,  N and PE 
conductors of the tested charging station. 
  The  measuring  terminals  must  only  be  used  for 
measurements. It is forbidden to draw current over a 
longer period or supply anything else. 
An appropriate measurement instrument is required.
6  Storage and Transport
   Improper storage  
Damage to  the  product and measuring  error  due to 
environmental inuences.       
Store the instrument in a protected location and only 
within the limits of permissible ambient conditions.
   Improper transport   
Damage to the product and measuring error.   
Transport the instrument only within the limits of per-
missible ambient conditions (temperature, humidity.   
Only transport the instrument with sufcient protection.
7  Cleaning
   Prior  to  cleaning,  ensure  that  instrument  is 
switched off and disconnected from external volt-
age supply and any other instruments connected 
(such as DUTs, control instruments, etc.).
  Never use acid detergents or dissolvent for cleaning.
If  the  instrument  is  dirty  after  daily  usage,  it  is  advised 
to  clean  it  by  using  a  humid  cloth  and  a  mild  household 
detergent.
8  Repair
If your instrument requires repair, please contact our service 
department.
  Loss of warranty and guarantee claims   
Unauthorized modication of the instrument is prohib-
ited. This also includes opening the instrument. If it 
can be ascertained that the tester has been opened 
by  unauthorized  personnel,  no  guarantee  claims 
can be honored  by  the  manufacturer  with  regard  to 
personal  safety,  measuring  accuracy,  compliance 
with applicable safety measures or any consequential 
damages.
The  instrument  may  only  be  repaired  or  opened  by  au-
thorized, qualied personnel  who are familiar with the  as-
sociated dangers. Original replacement parts may only be 
installed by authorized, qualied personnel.
9  Contact, Support and Service
Gossen  Metrawatt  GmbH  can  be  reached  directly 
and  simply  –  we  have  a  single  number  for  everything! 
Whether you  require support or  training, or have  an indi-
vidual  inquiry, we  can  answer  all  of  your  questions  here:  
+49-911-8602-0
Monday to Thursday:  8 a.m. to 4 p.m. 
Friday:  8 a.m. to 2 p.m.
Or contact us by e-mail at: info@gossenmetrawatt.com
Do you prefer support by e-mail?
Measuring and Test Technology:   
support@gossenmetrawatt.com
Industrial Measuring Technology:   
support.industrie@gossenmetrawatt.com
Please contact GMC-I Service GmbH for repairs, replace-
ment parts and calibration
1
:
+49-911-817718-0
Beuthener Str. 41, 90471 Nürnberg, Germany
service@gossenmetrawatt.com
https://www.gmci-service.com/en/
1   DAkkS calibration laboratory per DIN EN ISO/
IEC 17025 accredited by the Deutsche Akkred-
itierungsstelle GmbH under reference number 
D-K-15080-01-01.
Content
1  Safety Instructions
2  Application
3  Documentation
4  The instrument
5  Testing
6  Storage and Transport
7  Cleaning
8  Repair
9  Contact, Support and Service
1  Safety instructions
Read and follow these instructions carefully and completely 
in order to ensure safe and proper use.
The instructions must be made available to all persons who 
use the instrument.
Keep for future reference.
   Carefully  and  completely  read  and  adhere  to  the 
product documentation for the associated test/meas-
uring instrument.
   Use the product only for its intended purpose in ac-
cordance with this documentation and the documen-
tation for the associated test/measuring instrument.
   The device may only be used by qualied electricians 
in the commercial eld.
   The products and accessories of Gossen Metrawatt 
GmbH are  designed  to  ensure  optimum  compatibil-
ity  with  the  Gossen  Metrawatt  GmbH  products  that 
are  expressly  provided  for  them.  Unless  otherwise 
expressly conrmed in writing by  Gossen Metrawatt 
GmbH, they are not intended and suited for use with 
other products.
   The  respective  accident  prevention  regulations  
established by the professional associations for elec-
trical systems and equipment must be strictly met at 
all times.
   In order to avoid electrical shock, the valid safety and 
VDE regulations regarding excessive contact voltag-
es must receive utmost attention, when working with 
voltages exceeding 120 V (60 V) DC or 50 V (2  V) 
rms AC. The values in brackets are valid for limited 
Specyfikacje produktu
| Marka: | Gossen Metrawatt | 
| Kategoria: | Niesklasyfikowane | 
| Model: | METRALINE EVSE IT Z525M | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Gossen Metrawatt METRALINE EVSE IT Z525M, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Gossen Metrawatt
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         31 Grudnia 2025
                        
                    
                                                            
                        
                         16 Grudnia 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         3 Października 2024
                        
                    
                                                            
                        
                         3 Października 2024
                        
                    
                                                            Instrukcje Niesklasyfikowane
- DCS
- Firefield
- LandRoller
- Sinus Live
- Voltcraft
- Kwikset
- AVerMedia
- Premier
- Comelit
- Digium
- Galcon
- Musical Fidelity
- Teradek
- Viper
- Lofrans
Najnowsze instrukcje dla Niesklasyfikowane
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         29 Stycznia 2025