49W W W. H AY WA R D F L O W C O N T R O L . C O M • 1 . 8 8 8 . 4 2 9 . 4 6 3 5
HOUSING
Polyamide
OUTPUT SHAFT
Carbon Steel, Nickel Plated
MINIMUM AIR
PRESSURE
80 PSI
MAXIMUM AIR
PRESSURE
120 PSI
SEALS
Nitrile
CYCLE TIME
Half Second, Typical
AIR PORT
CONNECTIONS
1/4" NPT
TECHNICAL INFORMATIONTECHNICAL INFORMATION
SPECIFICATIONS
PMD Series
Double Acting
Pneumatic Actuators
ES UP TO 2"
Y VALVES UP TO 3"
ES
to-Open and Close
nt Thermoplastic Housing
icated Rack and Pinion
and Pinion Design
Works Mounting
noid Mounting
g Base
ith Optional Voltages
ual Override
• Auxiliary Limit Switch
• Cycle Speed Control
• Positioner
EXPLODED VIEW
P N E U M AT I C A C T U AT I O N A N D C O N T R O L S
M
A
N
U
A
L
O
V
E
R
R
I
D
E

50
Hayward is a registered trademark
of Hayward Industries, Inc.
© 2020 Hayward Industries, Inc.
USA: 1.888.429.4635 • Fax: 1.888.778.8410 • One Hayward Industrial Drive • Clemmons, NC 27012 • Email: hfcsales@hayward.com
Canada: 1.888.238.7665 • Fax: 1.905.829.3636 • 2880 Plymouth Drive • Oakville, ON L6H 5R4 • Email: hflowcanada@hayward.com
Visit us at: haywardflowcontrol.com
TOP
FRONT
SIDE
BOTTOM
U
L
R
D
P
øC
B
øA
A
TECHNICAL INFORMATION, CONTINUED
PMD Series
Double Acting Pneumatic Actuators
FOR BALL VALVES UP TO 2"
FOR BUTTERFLY VALVES UP TO 3"
DIMENSIONS
ACTUATOR OPERATING SYSTEMS
MODEL øA
in / mm
B
in / mm
C
in / mm
L
in / mm
P
in / mm
R
in / mm
PMD15 .551 / 14
ISO F05
1/4-20 x .512
UNC-ISO F05
ø1.969 / 50
ISO F05 6.299 / 4.370 / 3.386 / 160 111 86
Dimensions are subject to change without notice – consult factory for installation information
ACTUATOR SPECIFICATIONS
MODEL PMD15
Torque Output (in-lbs) @ 80 PSI 275
Enclosure Material Polyamide
Output Shaft Carbon Steel, Nickel Plated
Air Port Connections 1/4" NPT
Air Consumption (cu. in.) 22.0
Air Transfer Internal
Stroke Time (seconds) .5
Cycle Time 1/2 Second
Minimum Air Pressure 80 PSI
Maximum Air Pressure 120 PSI
Operation Rack and Pinion
Weight (lbs / ) 2.624 / kg 1.2
VALVE SELECTION CHART
SIZE*
in / DN
TB / TBH / CV / CVH SERIES
BALL VALVES
TW/LA SERIES
BALL VALVES
BYV SERIES
BUTTERFLY VALVES
1/2 - 2 PMD15 PMD15 N/A / 15 - 50
2 - 3 – – PMD15
* Actuator selection based on clean water @ 70°F

51W W W. H AY WA R D F L O W C O N T R O L . C O M • 1 . 8 8 8 . 4 2 9 . 4 6 3 5
SPECIFICATIONS
HOUSING
Polyamide
OUTPUT SHAFT
Carbon Steel, Nickel Plated
MINIMUM AIR
PRESSURE
80 PSI
MAXIMUM AIR
PRESSURE
120 PSI
SEALS
Nitrile
CYCLE TIME
Half Second, Typical
AIR PORT
CONNECTIONS
1/4" NPT
TECHNICAL INFORMATION
PMS Series
Spring Return
Pneumatic Actuators
FOR BALL VALVES UP TO 2"
KEY FEATURES
• Air to Spring Fail-Safe Operation
• Corrosion-Resistant Thermoplastic Housing
• Permanently Lubricated Rack and Pinion
• Manual Override
• Two-Piston Rack and Pinion Design
• Namur-Style Top-Works Mounting
• Namur-Style Solenoid Mounting
• Position Indicator
• Lightweight
• ISO5211 Mounting Base
OPTIONS
• Solenoid Valves with Optional Voltages
• Declutchable Manual Override
• Auxiliary Limit Switch
• Cycle Speed Control
• Positioner
EXPLODED VIEW
M
A
N
U
A
L
O
V
E
R
R
I
D
E
P N E U M AT I C A C T U AT I O N A N D C O N T R O L S
Specyfikacje produktu
Marka: | Hayward |
Kategoria: | Niesklasyfikowane |
Model: | PMD15 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Hayward PMD15, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Hayward
5 Października 2024
11 Września 2024
10 Września 2024
10 Września 2024
7 Września 2024
31 Sierpnia 2024
28 Sierpnia 2024
25 Sierpnia 2024
25 Sierpnia 2024
21 Sierpnia 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane Texas
- Niesklasyfikowane Ansco
- Niesklasyfikowane Megableu
- Niesklasyfikowane AmerBox
- Niesklasyfikowane Alogic
- Niesklasyfikowane Saitek
- Niesklasyfikowane Sencys
- Niesklasyfikowane Gallien-Krueger
- Niesklasyfikowane Umidigi
- Niesklasyfikowane One For All
- Niesklasyfikowane Exit Toys
- Niesklasyfikowane Toro
- Niesklasyfikowane Britax
- Niesklasyfikowane Auer Signal
- Niesklasyfikowane Karma
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025