Truma LevelCheck
EN Operating instructions
To be kept in the vehicle
Page 02

2EN
The device is not suitable for plastic gas cylinders, tank gas
cylinders that can be filled, gas tanks or butane gas cylinders
(camping gas).
To ensure reliable measurements, the measuring head
needs to be cleaned with a damp cloth (without a deter-
gent) every time before use.
A soiled measuring head can lead to inaccurate measure-
ments. Aluminium cylinders, in particular, transfer dust parti-
cles that can impact on the measuring process.
Soiled or rusty gas cylinders are usually difficult to measure.
The measuring process can also be impeded by the following:
– an invisible area of rust inside the gas cylinder
– a very thick coat of paint on the outside of the gas cylinder
– stickers on the outside of the gas cylinder
– (icy) condensation on the outside of the gas cylinder
– indentations or severely scratched gas cylinders
Cleaning the gas cylinder or taking the measurement at a dif-
ferent point is usually successful.
Determine the filling level
Determine the filling level by taking several individual meas-
urements at various heights on the gas cylinder (from the bot-
tom to the top).
Do not drag the device along the gas cylinder.
Truma LevelCheck – filling level indicator
3
2
4
5
7
6
1
1 = Ultrasound measuring head
2 = LED light (torch)
3 = Status LED (red / green / orange)
4 = On / off button for LED light
5 = Openings for wrist strap
(not included in the delivery)
6 = Battery compartment
7 = Screw for battery compartment
Intended use
Truma LevelCheck is a mobile filling level indicator for all (pro-
pane / butane – LPG) steel or aluminium gas cylinders with a di-
ameter of 200 to 350mm. The device recognises whether there
is liquid in the cylinder at the measuring point and indicates this.
Important notes
A gas cylinder is filled with max. 80% of its volume. The re-
sulting filling level of a full cylinder changes depending on the
gas mixture (ration of propane / butane) and the temperature.

3EN
A measurement is started by the pressing the measuring head (1)
horizontally onto the gas cylinder (confirmed by a beeping sound).
90°
The status LED (3) flashes orange during the measuring process.
The end of the measurement is indicated via a second beeping
tone and the measuring result is displayed on the status LED (3).
Status LED green – Liquid detected at the measuring point
Status LED red – No liquid or inaccurate measurement
The device switches off automatically after a measurement
has been taken.
LED light
The LED light (2) is switched on by pressing the button (4).
Re-pressing the button switches the LED light off again. The
LED light switches off automatically after around 5 minutes.
Undervoltage / malfunction
– The displayed measuring result flashes: The battery is low
(measurements can still be taken)
– The red status LED flashes and beeps 3 times: The battery is
empty (measurements can no longer be taken)
Battery change
Please only use leak-resistant batteries
(E-Block 9V), Type6 LR61, 6F22.
Unscrew the screw (7) from the lower shell. Push the lower
shell in the direction of the arrow and detach. Replace the
battery and when doing so, check the polarity of the wires.
Dispose of the empty battery correctly and separately from
the device.
An empty spent battery can leak and damage the de-
vice! Remove the battery from the device if the device
is not going to be used for a longer period.
The warranty will not apply to damage caused by leaking
batteries.
Disposal
Neither the appliance nor the batteries may be disposed
of with domestic refuse, instead they must be sent for
recycling separately via a collection point. By doing this
you are contributing towards reuse and recycling.
Technical data
Power supply
E-Block 9 V
Dimensions (W x H x D)
138 x 35 x 30 mm
Weight (incl. battery)
approx. 100 g
The right to effect technical modifications is reserved!
Specyfikacje produktu
Marka: | Truma |
Kategoria: | Niesklasyfikowane |
Model: | LevelCheck |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Truma LevelCheck, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Truma
1 Września 2024
29 Sierpnia 2024
28 Sierpnia 2024
28 Sierpnia 2024
27 Sierpnia 2024
17 Sierpnia 2024
13 Sierpnia 2024
Instrukcje Niesklasyfikowane
- Niesklasyfikowane Now TV
- Niesklasyfikowane Minn Kota
- Niesklasyfikowane Nabo
- Niesklasyfikowane Rug Doctor
- Niesklasyfikowane Planet Audio
- Niesklasyfikowane Michigan
- Niesklasyfikowane Metabo
- Niesklasyfikowane Muama
- Niesklasyfikowane PCTV Systems
- Niesklasyfikowane Spelsberg
- Niesklasyfikowane Jedo
- Niesklasyfikowane Röhm
- Niesklasyfikowane Kerbl
- Niesklasyfikowane Nautilus
- Niesklasyfikowane Hauck
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025