The JA-63E wired keypad  2 / 2  MKP51001 
The JA-63E digital bus wired keypad
The JA-63E keypad is designed to control and program alarm systems of 
Jablotron’s JA-6x series. The keypad is equipped with backlit keys, built-in LED 
signalling, acoustic signalling, and a display. It conveys information about the 
system status in a convenient way. The keypad communicates via the control 
panel digital bus. You can connect the keypad to the control panel via an RJ 
cable or via a standard communication cable connected to terminals. Multiple 
JA-63E keypads can be connected to a single control panel. 
Any undesirable mishandling of the keypad (like opening its housing or tea-
ring the keypad off its position) will trigger tamper signalling. In addition, the 
number of attempts to enter an access code is checked not to exceed a given 
limit. 
Installation 
Select the desired keypad location close to the building’s entrance.  
1.  Open the keypad’s rear housing (by pressing the two tabs on the left or 
right side). 
2.  Route all required cables through the hole in the rear housing and install 
the housing to the desired location. 
3.  Connect the digital bus cable either to the terminal board or to an RJ 
connector. 
4.  Close the keypad’s housing (attach the front housing on one side and 
push it on the other side). 
5.  Switching on the control panel power makes the keypad ready for op-
eration. 
Tabs
Tabs
SYSTEM  6 0
Installation notes: 
Multiple JA-63E keypads in the system must be wired in parallel. Inlet 
cables can be split directly in the control panel, in a converter, in the keypad or 
in a junction box. RJ cable connection and connection to terminals can be 
used in combination. 
A connecting cable must be wired so that the corresponding positions 
(terminals) are connected. When you use a self-made RJ cable, be careful to 
connect identically coloured wire ends to identically marked positions (termi-
nals). 
If the keypad does not function after being connected, disconnect the 
inlet cable and check if the corresponding positions (terminals) in the control 
panel and the keypad are connected. 
Operation 
The keypad can operate and program the system to the full extent as it is 
described in the control panel manual. 
The following table describes the meaning of symbols on the keypad LED 
indicators: 
 Alarm   Power supply 
 Tamper   Set (Armed) 
 Fault   Battery 
 Wireless communication indication 
Functions F1 through F0 can be used as described in the control panel ma-
nual. Besides this, there are 4 extra keys with the following functions: 
Setting (Arm-
ing)  
(equal to F1 
entry) 
Door opening  
(equal to F3 entry) 
Partial setting  
(equal to F2 
entry)   
Panic (access under 
duress) 
(equal to F7, before 
access code entry) 
 Remote system access 
The JA-63E keypad allows you to remotely operate or program a JA-6x 
system via a phone line using a JA-60U modem. Such operation requires the 
system to be equipped with a telephone communicator with the remote access 
feature enabled (see the security system installation manual). 
Note: Remote system access via the JA-63E keypad is only possible using a 
JA-60U modem of DY62012 version or higher. 
Connecting remotely to the system: Connect the JA-60U modem to the 
phone line. Connect the JA-63E keypad cable to the modem’s data connector. 
After powering up the modem, the keypad will show a u  on the display to 
indicate that it is ready to establish a connection. 
The initial connection is established by keying in: 
xxxxxxxx F1 y F2 ttt...t F3 nnn...n F d 
where: 
xxxxxxxx  is an 8-digit access code for system remote access 
y    answering machine bypass (a so-called second call) 0-
not bypassed, 1-bypassed 
ttt...t    call back tel. number – if call back is not requested just 
enter F3 after F2 
nnn...n  the remote system tel. number (a pause can be specified 
by keying in F0) 
d   dialling method: 4-tone, 5-pulse 
After the d parameter is entered, the modem will establish a connection 
and the keypad will display the remote system status. The keypad then beha-
ves the same way as if it had been connected directly to the system. Depen-
ding on the quality, the telephone line might be slower in its response.  A JA-
63 remote connection disables the 4 big keys on the keypad’s right side. Use 
keys F0 to F9 instead. 
The connection is terminated by pressing key  . 
A re-connection (using the same modem) is established by entering F6. The 
connection parameters are memorized. 
If you perform a call to a control panel which has the same access code 
but a different telephone number, you do not need to re-enter the whole con-
necting sequence. Instead, it is sufficient to key in nnn...n F4 – i.e. the control 
panel tel. number followed by one of the F4/F5 keys (depending on the 
tone/pulse dialling method). 
Technical specifications 
Connection  with a cable to the JA-6x digital bus connector 
Connecting cable  4 core cable with RJ connectors (4/4 1:1) or  
  ordinary telephone cable (terminals) 
Length of the inlet cable  max. 100 m when a paired cable is used  
Power supply  10 –14 V (taken from the digital bus) 
Power consumption  25mA  
Enclosure IP40 
Dimensions  125 x 145 x 30 mm 
Complies with    EN 50131-1, EN 50131-3  grade 2 
Environmental class  II indoor general -10 to +40°C 
EMC    EN 50130-4,EN 55022 
Contents of the kit:   JA-63E keypad, 4 m of connecting cable,  
  4 rawl plugs, 4 screws, 2 RJ-44 connectors. 
Accessories – for keypad connection (can be ordered separately):  
RJ-40 converter from RJ connector to 4 terminals 
RJ-21  RJ connector splitter (2/1) 
RJ-44  cable connector (4P/4C) 
RJ-00  crimping tool for RJ connectors 
CT-04  cable for RJ connectors 
JABLOTRON ALARMS a.s hereby declares that the JA-63E is in compliance 
with the essential requirements and other relevant provisions of Directive 
2004/108/EC. The original of the conformity assessment can be found at 
www.jablotron.com, Technical Support section. 
Note: Although this product does not 
contain any harmful materials we 
suggest you return the product to the 
dealer or directly to the producer after 
use. See www.jablotron.com for details. 
Specyfikacje produktu
| Marka: | Jablotron | 
| Kategoria: | Bezpieczeństwo | 
| Model: | JA-63E | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Jablotron JA-63E, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Bezpieczeństwo Jablotron
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         23 Września 2024
                        
                    
                                                            
                        
                         21 Września 2024
                        
                    
                                                            
                        
                         18 Września 2024
                        
                    
                                                            
                        
                         18 Września 2024
                        
                    
                                                            Instrukcje Bezpieczeństwo
- Wanscam
- One Concept
- Visonic
- Oplink
- Sonic Alert
- Heidemann
- Trust
- AXA
- Alhua - Dahua
- Secure Pro
- Dahua
- Ajax
- Siemens
- Home Protector
- Galaxy
Najnowsze instrukcje dla Bezpieczeństwo
                        
                         19 Lutego 2025
                        
                    
                                                            
                        
                         15 Stycznia 2025
                        
                    
                                                            
                        
                         15 Stycznia 2025
                        
                    
                                                            
                        
                         15 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         11 Stycznia 2025
                        
                    
                                                            
                        
                         5 Października 2024
                        
                    
                                                            
                        
                         2 Października 2024
                        
                    
                                                            
                        
                         28 Września 2024
                        
                    
                                                            
                        
                         28 Września 2024