Product description
Saves energy and reduces the risk of fires by shutting off all
connected devices. Connect your computer to the master out-
let and your screen, printer, scanner, etc. to the slave outlets.
Turning on your computer also turns on all devices connected
to the slave outlets.
- The threshold value of the master outlet can be
adjusted, 8-80 W.
- Safety shutters.
- Equipped with 1 master outlet and 5 earthed slave outlets.
- All outlets have built-in surge protection.
- Contains 4 varistors, 2 fuses, and 1 gas discharge tube.
- Two indicator lamps:
Blue - lights when the slave outlets are activated.
Green - lights when surge protection is functioning.
- 240 V / 13 A, max. 3120 W.
Safety
- The product is intended for indoor use only.
- Connected devices must be designed for 240 V AC, 50 Hz.
- If the green LED is unlit the surge protection has been trig-
gered and no longer offers protection. The extension lead’s
energy saving function is operative and the lead can be
used as normal but without the benefit of surge protection.
- If the blue LED does not come on, make sure that the
connected devices are turned on and that the rated power
is not less than 8 W.
- The device which is connected to the master outlet
should have a power consumption of between 8 and
80 W (or the lead’s automatic control will not work).
- The surge protector will not protect the device NOTE:
from excessively high transient voltage spikes or direct
lightning strikes.
Operation
Devices connected to the slave outlets will turn on when
the master outlet exceeds the threshold set by the adjusting
screw, and turn off when the load falls below the set value.
- Turning OFF OFF your computer also turns all devices
connected to the slave outlets.
- Turning your computer also turns all devices ON ON
connected to the slave outlets.
N.B.
- If you switch the device which is connected to the master
outlet to a device which does not have the same power
rating, you must readjust the threshold setting again accor-
dingly. If both devices have the same power consumption
no adjustment is needed.
Troubleshooting
The green “Protect” – indictor light is not lit:
1. The surge protector is not working. The function may have
been disabled by lightning or overvoltage.
The blue “Slave” – indicator light is not lit after adjusting
the threshold setting. Check:
1. That the device connected to the master outlet is turned on.
2. That the connected device does not have a power con-
sumption of less than 8 W (in these cases the automatic
switch will not work).
Disposal
Follow local ordinances when disposing of this product.
If you are unsure of how to dispose of this product, please
contact your municipality.
Specifications
Rated voltage 240 V AC, 50 Hz, 13 A
Max load Slave Max. 3120 W
Max load Master 550 W
Threshold value min / max 8 W 80 / W (master outlet)
Protection Class II
Uoc P-N = 2.5 kV
P/N-E = 5.0 kV
Up P-N = 2.0 kV
P/N-E = 2.5 kV
Uc 240 V AC
1. First make sure the devices you are connecting are
turned off.
2. Connect the plug to a wall socket.
3. Connect the device (e.g. your computer) which you want
to use to turn you other devices on/off to the master
outlet. The green LED should light and indicate that the
surge protection is functioning.
4. Turn on the device connected to the master outlet.
5. Begin by first turning the adjusting screw anticlockwise
to max. Then slowly turn the adjusting screw clockwise
to adjust the threshold for the on/off feature. Stop when
the blue LED lights. The LED indicates that the setting
is correct.
6. Connect the rest of the devices (monitor, printer, etc.)
to the slave outlets.
7. Switch on the connected device/s.
Adjusting screw
Green LED
Blue LED
Specyfikacje produktu
| Marka: | Cotech |
| Kategoria: | Niesklasyfikowane |
| Model: | EMP306SA |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Cotech EMP306SA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Cotech
1 Września 2024
31 Sierpnia 2024
31 Sierpnia 2024
31 Sierpnia 2024
31 Sierpnia 2024
30 Sierpnia 2024
30 Sierpnia 2024
29 Sierpnia 2024
28 Sierpnia 2024
28 Sierpnia 2024
Instrukcje Niesklasyfikowane
- Sunstech
- Cobra
- Senal
- Tempo
- Maxwell
- ISDT
- Laurastar
- Lorelli
- Silva
- WHALE
- HK Audio
- Euromaid
- Eller
- ASI
- Viridian
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025